3. SETUP continued
After highlighting Power or a source, press SELECT and use the 34 buttons to move from one path to
another. To set the condition, use the 56 buttons to change the ” to a “*”. Don’t forget: In the root menu
you have to set ALL TRIGGERS to Enabled for the triggers to work.
Changes to the trigger setup do not take effect until exiting from the setup menu, to avoid unnecessary
rapid turning off and on of triggers while making changes.
Example: Activate Trigger2 when DVD1 is selected in MAIN.
Enter the setup menu. Go to TRIGGER / IR / RS232 and press SELECT.
Upon entering this menu item, ALL TRIGGERS will be highlighted in red.
Use the 34 buttons to change to Enabled.
Press the 6 button to go to SET TRIGGER 2. Press SELECT.
Use the 56 buttons to go to DVD1. Press SELECT.
Use the 56 buttons to change the “to *”.
Press BACK twice to leave this submenu.
Set IR Inputs:
This allows you to enable or disable the processor’s infra-red inputs. Being able to do so can be useful when
an IR receiver connected to the processor is in the same room as the processor. In this case the processor
can receive two IR signals for the same command one through the front and one through the back. The
double-command may affect responsiveness – disabling the front IR solves this problem.
After highlighting an IR input, press SELECT and use the 34 buttons to move from one path to another. To
turn the input off, use the 56 buttons to change the *to a ”. Do this through the front panel, since
remote control commands are ineffective once an IR sensor is turned off.
If the processor does not respond to remote control commands, enter the Setup using the front panel
buttons, go to the TRIGGER / IR / RS232 menu then SET IR-INPUTS, and make sure the
FRONT IR settings are set to “*”. Try this before contacting technical support (see also section 5.6).
Baud Rate and Flow Control (normally for use only by custom installers):
The Baud Rate (adjustable from 1200 to 115200 bps), and Flow Control (RTS, CTS, or None), allow
configuration of the serial port communication parameters.
RS-232 TX Status (normally for use only by custom installers):
When On, all commands, status changes, and control information are echoed through the RS-232 port.
11e. SET IR-INPUTS
MAIN Z2 Z3
a. FRONT IR: * * *
b. REAR IR 1: * * *
c. REAR IR 2: * * *
d. REAR IR 3: * * *